	"audit_type":	"MHEA",
	"audit_id":	2259,
	"audit_number":	3227,
	"length":	76,
	"width":	15,
	"energy_calc_counter":	13,
	"pre_heat":	43.7,
	"pre_cool":	0,
	"pre_base":	940.9,
	"post_heat":	31.4,
	"post_cool":	0,
	"post_base":	341.6,
	"num_measure":	8,
	"measures":	[{
			"index":	1,
			"measure_id":	43,
			"component_id":	0,
			"audit_section_id":	29,
			"measure":	"Water Heater Tank Insulation",
			"components":	"Water Heater",
			"heating_mmbtu":	0,
			"heating_sav":	0,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	599.3,
			"baseload_sav":	43,
			"total_mmbtu":	2.045,
			"savings":	43,
			"cost":	40,
			"sir":	13.695,
			"lifetime":	13,
			"qtym":	1,
			"qtyl":	1,
			"qtyi":	1,
			"costum":	15,
			"costul":	25,
			"costi1":	0,
			"costi2":	0,
			"desci2":	"",
			"typei2":	0,
			"costi3":	0,
			"desci3":	"",
			"typei3":	0
		}, {
			"index":	2,
			"measure_id":	9,
			"component_id":	0,
			"audit_section_id":	7,
			"measure":	"Floor Cellulose Loose Insulation",
			"components":	"Floor",
			"heating_mmbtu":	6.912,
			"heating_sav":	145.34,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	6.912,
			"savings":	145.34,
			"cost":	755,
			"sir":	3.614,
			"lifetime":	20,
			"qtym":	65,
			"qtyl":	65,
			"qtyi":	1,
			"costum":	7,
			"costul":	0,
			"costi1":	300,
			"costi2":	0,
			"desci2":	"",
			"typei2":	0,
			"costi3":	0,
			"desci3":	"",
			"typei3":	0
		}, {
			"index":	3,
			"measure_id":	2,
			"component_id":	0,
			"audit_section_id":	74,
			"measure":	"General Air Sealing",
			"components":	"General Air",
			"heating_mmbtu":	0.571,
			"heating_sav":	12.01,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	0.571,
			"savings":	12.01,
			"cost":	37,
			"sir":	3.221,
			"lifetime":	10,
			"qtym":	1,
			"qtyl":	1,
			"qtyi":	1,
			"costum":	0,
			"costul":	0,
			"costi1":	0,
			"costi2":	37,
			"desci2":	"Infiltration Reduction",
			"typei2":	2,
			"costi3":	0,
			"desci3":	"",
			"typei3":	0
		}, {
			"index":	4,
			"measure_id":	37,
			"component_id":	0,
			"audit_section_id":	77,
			"measure":	"Tune Up Heating System",
			"components":	"HS1",
			"heating_mmbtu":	3.908,
			"heating_sav":	82.18,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	3.908,
			"savings":	82.18,
			"cost":	125,
			"sir":	1.933,
			"lifetime":	3,
			"qtym":	1,
			"qtyl":	1,
			"qtyi":	1,
			"costum":	25,
			"costul":	100,
			"costi1":	0,
			"costi2":	0,
			"desci2":	"",
			"typei2":	0,
			"costi3":	0,
			"desci3":	"",
			"typei3":	0
		}, {
			"index":	5,
			"measure_id":	21,
			"component_id":	0,
			"audit_section_id":	67,
			"measure":	"Door Replacement",
			"components":	"SE",
			"heating_mmbtu":	0.829,
			"heating_sav":	17.44,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	0.829,
			"savings":	17.44,
			"cost":	218,
			"sir":	1.163,
			"lifetime":	15,
			"qtym":	1,
			"qtyl":	1,
			"qtyi":	1,
			"costum":	125,
			"costul":	60,
			"costi1":	33,
			"costi2":	0,
			"desci2":	"",
			"typei2":	0,
			"costi3":	0,
			"desci3":	"",
			"typei3":	0
		}, {
			"index":	6,
			"measure_id":	24,
			"component_id":	0,
			"audit_section_id":	67,
			"measure":	"Storm Door",
			"components":	"SE",
			"heating_mmbtu":	0.079,
			"heating_sav":	1.67,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	0.079,
			"savings":	1.67,
			"cost":	130,
			"sir":	0.128,
			"lifetime":	10,
			"qtym":	1,
			"qtyl":	1,
			"qtyi":	1,
			"costum":	100,
			"costul":	30,
			"costi1":	0,
			"costi2":	0,
			"desci2":	"",
			"typei2":	0,
			"costi3":	0,
			"desci3":	"",
			"typei3":	0
		}, {
			"index":	7,
			"measure_id":	51,
			"component_id":	1974,
			"audit_section_id":	37,
			"measure":	"8680 Carbon Monoxide Alarm Qty:2",
			"components":	"Itemized Cost",
			"heating_mmbtu":	0,
			"heating_sav":	0,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	0,
			"savings":	0,
			"cost":	63.16,
			"sir":	0,
			"lifetime":	0,
			"qtym":	1,
			"qtyl":	1,
			"qtyi":	1,
			"costum":	0,
			"costul":	0,
			"costi1":	0,
			"costi2":	63.16,
			"desci2":	"Carbon monoxide alarm (+)",
			"typei2":	0,
			"costi3":	0,
			"desci3":	"",
			"typei3":	0
		}, {
			"index":	8,
			"measure_id":	51,
			"component_id":	1975,
			"audit_section_id":	37,
			"measure":	"8691 LP Alarm Qty:",
			"components":	"Itemized Cost",
			"heating_mmbtu":	0,
			"heating_sav":	0,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	0,
			"savings":	0,
			"cost":	51.84,
			"sir":	0,
			"lifetime":	0,
			"qtym":	1,
			"qtyl":	1,
			"qtyi":	1,
			"costum":	0,
			"costul":	0,
			"costi1":	0,
			"costi2":	51.84,
			"desci2":	"LP alarm (+)",
			"typei2":	0,
			"costi3":	0,
			"desci3":	"",
			"typei3":	0
		}],
	"num_measure_adj":	0,
	"measures_adj":	[],
	"num_an_sav":	8,
	"an_sav":	[{
			"index":	1,
			"measure_index":	1,
			"measure":	"Water Heater Tank Insulation",
			"components":	"Water Heater",
			"heating_mmbtu":	0,
			"heating_sav":	0,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	599.3,
			"baseload_sav":	43,
			"total_mmbtu":	2.045,
			"total_lc_sav":	547.81
		}, {
			"index":	2,
			"measure_index":	2,
			"measure":	"Floor Cellulose Loose Insulation",
			"components":	"Floor",
			"heating_mmbtu":	6.912,
			"heating_sav":	145.34,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	6.912,
			"total_lc_sav":	2728.37
		}, {
			"index":	3,
			"measure_index":	3,
			"measure":	"General Air Sealing",
			"components":	"General Air",
			"heating_mmbtu":	0.571,
			"heating_sav":	12.01,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	0.571,
			"total_lc_sav":	119.19
		}, {
			"index":	4,
			"measure_index":	4,
			"measure":	"Tune Up Heating System",
			"components":	"HS1",
			"heating_mmbtu":	3.908,
			"heating_sav":	82.18,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	3.908,
			"total_lc_sav":	241.61
		}, {
			"index":	5,
			"measure_index":	5,
			"measure":	"Door Replacement",
			"components":	"SE",
			"heating_mmbtu":	0.829,
			"heating_sav":	17.44,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	0.829,
			"total_lc_sav":	253.45
		}, {
			"index":	6,
			"measure_index":	6,
			"measure":	"Storm Door",
			"components":	"SE",
			"heating_mmbtu":	0.079,
			"heating_sav":	1.67,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	0.079,
			"total_lc_sav":	16.58
		}, {
			"index":	7,
			"measure_index":	7,
			"measure":	"8680 Carbon Monoxide Alarm Qty:2",
			"components":	"Itemized Cost",
			"heating_mmbtu":	0,
			"heating_sav":	0,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	0,
			"total_lc_sav":	0
		}, {
			"index":	8,
			"measure_index":	8,
			"measure":	"8691 LP Alarm Qty:",
			"components":	"Itemized Cost",
			"heating_mmbtu":	0,
			"heating_sav":	0,
			"cooling_kwh":	0,
			"cooling_sav":	0,
			"baseload_kwh":	0,
			"baseload_sav":	0,
			"total_mmbtu":	0,
			"total_lc_sav":	0
		}],
	"num_an_asav":	0,
	"an_asav":	[],
	"num_sir":	8,
	"sir":	[{
			"index":	1,
			"measure_index":	1,
			"group":	2,
			"measure":	"Water Heater Tank Insulation",
			"components":	"Water Heater",
			"savings":	43,
			"cost":	40,
			"sir":	13.695,
			"ccost":	40,
			"csir":	13.695,
			"npv":	507.81
		}, {
			"index":	2,
			"measure_index":	2,
			"group":	2,
			"measure":	"Floor Cellulose Loose Insulation",
			"components":	"Floor",
			"savings":	145.34,
			"cost":	755,
			"sir":	3.614,
			"ccost":	795,
			"csir":	4.121,
			"npv":	1973.37
		}, {
			"index":	3,
			"measure_index":	3,
			"group":	2,
			"measure":	"General Air Sealing",
			"components":	"General Air",
			"savings":	12.01,
			"cost":	37,
			"sir":	3.221,
			"ccost":	832,
			"csir":	4.081,
			"npv":	82.19
		}, {
			"index":	4,
			"measure_index":	4,
			"group":	2,
			"measure":	"Tune Up Heating System",
			"components":	"HS1",
			"savings":	82.18,
			"cost":	125,
			"sir":	1.933,
			"ccost":	957,
			"csir":	3.8,
			"npv":	116.61
		}, {
			"index":	5,
			"measure_index":	5,
			"group":	2,
			"measure":	"Door Replacement",
			"components":	"SE",
			"savings":	17.44,
			"cost":	218,
			"sir":	1.163,
			"ccost":	1175,
			"csir":	3.311,
			"npv":	35.45
		}, {
			"index":	6,
			"measure_index":	6,
			"group":	2,
			"measure":	"Storm Door",
			"components":	"SE",
			"savings":	1.67,
			"cost":	130,
			"sir":	0.128,
			"ccost":	1305,
			"csir":	2.994,
			"npv":	-113.42
		}, {
			"index":	7,
			"measure_index":	7,
			"group":	3,
			"measure":	"8680 Carbon Monoxide Alarm Qty:2",
			"components":	"Itemized Cost",
			"savings":	0,
			"cost":	63.16,
			"sir":	0,
			"ccost":	1305,
			"csir":	2.994,
			"npv":	-63.16
		}, {
			"index":	8,
			"measure_index":	8,
			"group":	3,
			"measure":	"8691 LP Alarm Qty:",
			"components":	"Itemized Cost",
			"savings":	0,
			"cost":	51.84,
			"sir":	0,
			"ccost":	1305,
			"csir":	2.994,
			"npv":	-51.84
		}],
	"num_asir":	0,
	"asir":	[],
	"num_material":	6,
	"material":	[{
			"index":	1,
			"measure_index":	1,
			"material_id":	40,
			"material":	"Water Heater Tank Insulation Wrap",
			"type":	"",
			"quantity":	1,
			"units":	"Each"
		}, {
			"index":	2,
			"measure_index":	2,
			"material_id":	3,
			"material":	"Floor Cellulose Loose Insulation",
			"type":	"",
			"quantity":	65,
			"units":	"Bag"
		}, {
			"index":	3,
			"measure_index":	3,
			"material_id":	17,
			"material":	"General Air Sealing",
			"type":	"",
			"quantity":	1,
			"units":	"Each"
		}, {
			"index":	4,
			"measure_index":	4,
			"material_id":	19,
			"material":	"Tune Up Heating System",
			"type":	"",
			"quantity":	1,
			"units":	"Each"
		}, {
			"index":	5,
			"measure_index":	5,
			"material_id":	8,
			"material":	"Door Replacement",
			"type":	"",
			"quantity":	1,
			"units":	"Each Door"
		}, {
			"index":	6,
			"measure_index":	6,
			"material_id":	9,
			"material":	"Storm Door",
			"type":	"",
			"quantity":	1,
			"units":	"Each Door"
		}],
	"num_amaterial":	0,
	"amaterial":	[],
	"num_message":	8,
	"message":	[{
			"index":	1,
			"msg":	"MHEA assumes that infiltration reduction will be performed in parallel to measures selected by the audit and according to guidelines chosen by the auditor.  MHEA can evaluate the cost-effectiveness of infiltration reduction efforts, but it will not direct the work."
		}, {
			"index":	2,
			"msg":	"The audit strongly suggests, but does not necessarily require, the use of existing infiltration reduction procedures using a blower-door. The blower-door establishes if infiltration reduction is necessary, then helps locate leaks and monitor progress in their elimination."
		}, {
			"index":	3,
			"msg":	"Manual J sizing based on 70F indoor and  -4F outdoor temp"
		}, {
			"index":	4,
			"msg":	"Base case duct loss fraction (%):   0"
		}, {
			"index":	5,
			"msg":	"Retrofit case duct loss fraction (%):   0"
		}, {
			"index":	6,
			"msg":	"Sizing estimate are general guidelines only"
		}, {
			"index":	7,
			"msg":	"Sizing estimate should be review by qualified heating contractor"
		}, {
			"index":	8,
			"msg":	"(+) in the Materials list indicates there are more related User Defined Materials"
		}],
	"num_manj":	8,
	"manj":	[{
			"index":	0,
			"heatcool":	"heat",
			"type":	"Wall",
			"name":	"",
			"area_vol":	0,
			"pre_load":	5742.8,
			"post_load":	5742.8
		}, {
			"index":	1,
			"heatcool":	"heat",
			"type":	"Floor",
			"name":	"",
			"area_vol":	0,
			"pre_load":	5635.8,
			"post_load":	3172.3
		}, {
			"index":	2,
			"heatcool":	"heat",
			"type":	"Roof",
			"name":	"",
			"area_vol":	0,
			"pre_load":	4595.5,
			"post_load":	4595.5
		}, {
			"index":	3,
			"heatcool":	"heat",
			"type":	"Windows",
			"name":	"",
			"area_vol":	0,
			"pre_load":	4235.6,
			"post_load":	4235.6
		}, {
			"index":	4,
			"heatcool":	"heat",
			"type":	"Doors",
			"name":	"",
			"area_vol":	0,
			"pre_load":	596.7,
			"post_load":	400
		}, {
			"index":	5,
			"heatcool":	"heat",
			"type":	"Infiltration",
			"name":	"",
			"area_vol":	0,
			"pre_load":	2103.1,
			"post_load":	1726.5
		}, {
			"index":	6,
			"heatcool":	"heat",
			"type":	"Duct Loss",
			"name":	"",
			"area_vol":	0,
			"pre_load":	0,
			"post_load":	0
		}, {
			"index":	7,
			"heatcool":	"heat",
			"type":	"Total",
			"name":	"",
			"area_vol":	0,
			"pre_load":	22909.5,
			"post_load":	19872.7
		}],
	"heat_comp_units":	"",
	"heat_dd_base":	0,
	"num_heat_comp":	0,
	"heat_comp":	[],
	"cool_comp_units":	"",
	"cool_dd_base":	0,
	"num_cool_comp":	0,
	"cool_comp":	[],
	"num_used_fuel":	1,
	"used_fuel":	[{
			"fuel_name":	"Propane",
			"fuel_cost":	1.926,
			"fuel_cost_units":	"$/Gal",
			"fuel_cost_per_mmbtu":	21.0262
		}]
}